{"action":"create","ckan_id":null,"date_created":"Fri, 03 Apr 2026 12:09:04 GMT","date_finished":null,"harvest_job_id":"52de7078-9ed3-4de6-8e65-213e11814947","harvest_source_id":"3dddf3ae-84a3-4731-88b4-6a0b57d0e503","id":"4bfebeaf-2e0a-46ca-bea1-5394ab9f0bbe","identifier":"https://datainventory.usbr.gov/rise/item/6288","parent_identifier":null,"source_hash":"c64235477cb8292289b67848814207d0c97dd3207d5ecf1b3b3294fc9f374b2f","source_raw":"{\"accessLevel\": \"public\", \"accrualPeriodicity\": \"irregular\", \"bureauCode\": [\"010:10\"], \"contactPoint\": {\"@type\": \"vcard:Contact\", \"fn\": \"RISE Team\", \"hasEmail\": \"mailto:data@usbr.gov\"}, \"description\": \"Dielectric Frequency Response (DFR) testing has become an accepted test for analyzing oil filled power transformer insulation which has sparked interest in the rotating machine community. DFR testing provides similar test points compared to traditional test methods but performed at much lower test voltages. This study\\u2019s primary goal was to determine if DFR testing could provide equivalent test results to traditional test methods. Results from the study are inconsistent with respect to aligning with traditional rotating machine test methods. At times the results would correlate well, and others would differ greatly. Additional data points and study would be required to determine if these inconsistencies continue, the data correlates, or differs from traditional methods.\", \"distribution\": [{\"@type\": \"dcat:Distribution\", \"accessURL\": \"https://data.usbr.gov/catalog/4431/item/6288\", \"description\": \"Landing page for \\\"S&T Project 1862 Final Report: Dielectric Frequency Response of Generator Stator Windings\\\"\", \"mediaType\": \"text/html\", \"title\": \"RISE Item Details Page URL for \\\"S&T Project 1862 Final Report: Dielectric Frequency Response of Generator Stator Windings\\\"\"}, {\"@type\": \"dcat:Distribution\", \"description\": \"\\\"S&T Project 1862 Final Report: Dielectric Frequency Response of Generator Stator Windings\\\" as a PDF file\", \"downloadURL\": \"https://data.usbr.gov/rise/content-rise-public/rise/catalog-item/binary/ST FInal Report Template - UPDATED March 2020 DFR 1862.pdf\", \"mediaType\": \"application/pdf\", \"title\": \"PDF File for \\\"S&T Project 1862 Final Report: Dielectric Frequency Response of Generator Stator Windings\\\"\"}], \"identifier\": \"https://datainventory.usbr.gov/rise/item/6288\", \"keyword\": [\"Dielectric Frequency Response (DFR)\", \"Rotating Machines\", \"Stator Windings\"], \"landingPage\": \"https://data.usbr.gov/catalog/4431/item/6288\", \"modified\": \"2021-06-07T17:49:23Z\", \"publisher\": {\"@type\": \"org:Organization\", \"name\": \"Bureau of Reclamation\"}, \"spatial\": \"{\\\"type\\\":\\\"Polygon\\\",\\\"coordinates\\\":[[[-105.12484,39.72238],[-105.1217,39.72366],[-105.1199,39.72123],[-105.12164,39.72052],[-105.12285,39.72213],[-105.12431,39.72153],[-105.12484,39.72238]]]}\", \"title\": \"S&T Project 1862 Final Report: Dielectric Frequency Response of Generator Stator Windings\"}","source_transform":null,"status":"error"}
